What you do is collect what comes out of the bottom of the column in a whole series of labelled tubes. How big each sample is will obviously depend on how big the column is - you might collect 1 cm 3 samples or 5 cm 3 samples or whatever is appropriate. You can then take a drop from each solution and make a thin layer chromatogram from it. You would place the drop on the base line alongside a drop from a pure sample of the compound that you are making. By doing this repeatedly, you can identify which of your samples collected at the bottom of the column contain the desired product, and only the desired product.
Once you know this, you can combine all of the samples which contain your pure product, and then remove the solvent. How you would separate the solvent from the product isn't directly relevant to this topic and would vary depending on their exact nature - so I'm not even going to attempt a generalisation.
Jim Clark Chemguide. The column In thin layer chromatography, the stationary phase is a thin layer of silica gel or alumina on a glass, metal or plastic plate. Using the Column Suppose you wanted to separate a mixture of two colored compounds - one yellow, one blue. Then you open the tap again so that the colored mixture is all absorbed into the top of the packing material, so that it might look like this: Next you add fresh solvent to the top of the column, trying to disturb the packing material as little as possible.
Explaining what is happening This assumes that you have read the explanation for what happens during thin layer chromatography. What if you want to collect the blue compound as well? The polar solvent will compete for space on the silica gel or alumina with the blue compound. Any space temporarily occupied by solvent molecules on the surface of the stationary phase isn't available for blue molecules to stick to and this will tend to keep them moving along in the solvent. There will be a greater attraction between the polar solvent molecules and the polar blue molecules.
This will tend to attract any blue molecules sticking to the stationary phase back into solution. Column chromatography is a convenient and versatile method for purifying compounds.
This method separates compounds based on polarity. By exploiting differences in the polarity of molecules, column chromatography can facilely separate compounds by the rate at which the compounds traverse through the stationary phase of the column. One of the benefits of column chromatography especially when compared to recrystallization is that very little about the compounds needs be known prior to the purification process.
The other advantage to using column chromatography is that it can be used to purify both solids and oils, while recrystallization can only be used to purify solids. This technique can also be used to isolate a number of compounds from a mixture. Column chromatography is one of the most convenient and widely used methods for purifying compounds.
Often, synthetic reactions will produce multiple products and column chromatography can be used to isolate each of the compounds for further examination.
Column chromatography is extremely valuable when synthesizing or isolating novel compounds, as very little needs to be known about a compound and its' physical properties prior to the purification process. The pharmaceutical industry routinely uses column chromatography to purify compounds as part of its early stage drug development process.
The Rf value should be between 0. Organic Chemistry. Column Chromatography. To learn more about our GDPR policies click here. If you want more info regarding data storage, please contact gdpr jove. Your access has now expired. Provide feedback to your librarian. If you have any questions, please do not hesitate to reach out to our customer success team. Login processing This is a sample clip.
Sign in or start your free trial. Previous Video Next Video. Overview Source: Laboratory of Dr. Jimmy Franco - Merrimack College Column chromatography is one of the most useful techniques for purifying compounds.
Log in or Start trial to access full content. Solvent The rate at which a compound traverses through the column is highly dependent on the mobile phase being utilized. Selecting a Solvent System Identify a solvent system that produces a retardation factor R f between 0. Start with either ethyl acetate or dichloromethane as the mobile phase for the TLC experiment.
If the R f is greater than 0. If the R f is less than 0. The optimal solvent system may require a mixture of two solvents. Silica Gel Slurry Pour the silica gel into an Erlenmeyer flask. The weight of the packing material should be roughly 50x that of the sample being separated. If the compounds being separated have very similar R f values, then it may require using a larger amount of silica per sample, which is the case in this example.
Place 10 g of silica in the Erlenmeyer flask, since 50 mg of sample 45 mg of fluorenone and 5 mg of tetraphenylporphyrin are being isolated. Add enough solvent to ensure that all of the silica gel is well solvated.
The silica will not dissolve, but the mixture will be visually noticeable when solvated. Once the solvent has been added swirl the Erlenmeyer flask to ensure that all of the silica is well solvated. Preparation of the Column Select the appropriately sized column. Typically the column should be filled about half way with silica gel slurry. The larger the sample being purified, the larger the column required.
Plug the bottom of the column with a piece of glass wool. Using a long rod, make sure the wool is firmly lodged in the bottom of the column just above the stopcock. Once the wool is firmly in place, apply a thin layer of sand over the glass wool. Note: If the column is equipped with a glass frit above the stopcock, this step should be omitted. Clamp the column in the vertical position to a ring stand. Using a funnel, gently pour the prepared slurry of silica gel into the column.
You may need to add additional solvent to transfer the slurry from the Erlenmeyer flask to the column. Using a pipette, wash down any silica gel that sticks to the sides of the column. As the silica gel is settling in the column, gently tap the sides of the column to ensure that the silica gel packs tightly and excludes any air bubbles. Open the stopcock and allow solvent to drain into a clean Erlenmeyer flask until just before the silica gel and the solvent front meet.
The silica gel should never go dry until the procedure is complete. Place a thin layer of sand on top of the silica gel Figure 1. Using a pipette, wash down any sand that may have stuck to the sides of the column. Drain any additional solvent until the sand is dry, but not down to the silica gel layer.
Adding the Sample to the Column Dissolve the sample in the smallest amount of solvent possible using the same solvent that was used to make the silica gel slurry. Using a pipette, gently add the sample to the top of the column. Once the sample has been applied to the top of the column, open the stopcock and allow the solvent to drain through the sand layer but not the silica gel layer. Use a very small amount of solvent to wash down any sample that may have clung to the sides of the column.
Drain this additional solvent through the sand layer as well. Eluting the Sample through the Column Using a pipette, very gently add 4—5 mL of solvent in such a manner that does not disturb the sand layer. Place a funnel at the top of the column and very slowly and gently fill the remainder of the column with solvent.
Open the stopcock and allow the solvent to drain through the column. Begin collecting the mobile phase as it drains from the column into test tubes. Test tubes should be placed in a test tube rack in a sequential manner. Add additional solvent to the top of the column as needed until all the desired compounds have eluted from the column.
Recovering the Constituents If the compounds are colored, then they can be visually identified. However, if the compounds are colorless, they will have to be identified using ulta-visible UV light if the compounds contain conjugation or with the appropriate stain.
The purity of the compounds can be verified using thin layer chromatography. Identify the test tubes that contain the desired compound s. It has an opening at the top where you can pour things in; a stopcock at the bottom, which I currently have shown in the closed position; and also a flask at the bottom to collect whatever it is you're using.
But it doesn't have to be a flask. You could use test tubes or really any other piece of glassware you'd like. So how do we begin? First, we need to pack this column full of some kind of filtration material, but we also want to make sure that that stuff doesn't just run through and spill into the flask. So first, you want to put a little cotton ball at the very bottom. This is very small, and usually what you end up doing is taking a long stick and just kind of ramming it right up against the stopcock.
Next, what I'd put in is a fine layer of sand. You want to try to get this to be as horizontal as possible, not tilted or slanted-- and I'll explain that later on-- but you want to do that with any layer you're adding onto the column.
They should all be perpendicular to your column. Next, what you'd do is add in the silica. The silica will take up most of your column, and you would be using that to fill almost all of it, just pouring it all in until it reaches a line of, say, about here.
Lastly, you'd pour your solvent into the column and make sure that the column is kept wet at all times, because if it runs dry and cracks, it can cause running and mixing of bands. So you would have your solvent line at about here, because if your column dries out it can crack. And what you'll see is that this is actually going through-- again, as I said-- the whole column. But this looks a little bit messy, so let me just clean that up for a minute.
Next, what we'll want to do is load the column with the actual product that we're using. And how do we do that? You can actually drop it in with a pipette, because you want to make sure that the layer is very even. So let's draw it out here. On top, you have this fine layer that you're dropping in on top of silica gel. But how can I push this through the column and into the flask?
0コメント